All-round monitoring for adult, pediatric and neonatal patient Monitor model CMS-8000

All-round monitoring for adult, pediatric and neonatal patient Monitor model CMS-8000

    • All-round monitoring for adult, pediatric and neonatal patient Monitor model CMS-8000
    • All-round monitoring for adult, pediatric and neonatal patient Monitor model CMS-8000
  • All-round monitoring for adult, pediatric and neonatal patient Monitor model CMS-8000

    Product Details:

    Place of Origin: China
    Brand Name: Huge & OEM
    Certification: CE and FDA
    Model Number: CMS8000

    Payment & Shipping Terms:

    Minimum Order Quantity: 1
    Price: 500USD
    Packaging Details: Color gift packing plus anlimum box
    Delivery Time: 3days upon receipt Payment
    Payment Terms: T/T, Paypal, Western Union
    Supply Ability: 100pcs/day
    Detailed Product Description

     

     

    All-round monitoring for adult, pediatric and neonatal patient Monitor model CMS-8000

    Introduction
    PM70 Patient Monitor can be used for all-round monitoring for adult, pediatric and neonatal for ECG, NIBP and SpO2, etc.
    Features
    ■All-round monitoring for adult, pediatric and neonatal
    ■3.5'' (320×240) TFT LCD
    ■Operate with button and touch screen
    ■Review of data list and trend graph
    ■Configuring interface as user's requirements
    ■Audible and visual alarm for each parameter, and upper and lower limit of alarm can be set
    ■Built-in rechargeable Li-polymer battery for uninterrupted monitoring
    Performance
    ECG
    ■3-lead and 5-lead are optional.
    ■Waveform display: dual-lead/full-lead
    ■Gain selection: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV
    ■Measurement range for Heart rate(HR): 30bpm~300bpm, error: ±1bpm or ±1%, whichever is greater.
    ■Upper and lower limit for alarm range: 30bpm~300bpm, resolution: 1bpm
    ■Input current: ≤0.1μA
    ■Enduring polarization voltage: ±300mV, sensitivity range: ±5%.
    ■CMRR: filter mode(surgery, monitoring)≥80dB
    ■Frequency response: 1~75Hz(+0.4dB,-3dB)
    ■Low-frequency characteristic: time constant≥3.2s
    ■Analysis function: heart rate, arrhythmia analysis, S-T segment analysis
    ■S-T segment range: -2.0mV~2.0mV
    Blood Pressure
    ■Measurement method: Oscillometry
    ■Measurement mode: manual/auto/continuous
    ■Auto measurement interval: adjustable from 1 to 90 minutes
    ■Resolution: 1mmHg
    ■Accuracy: Maximum Mean deviation≤±5mmHg, Maximum Standard deviation≤8mmHg
    ■Self-check function
    ■Overpressure protection: double protection for software and hardware
    a. Range
    Adult:
    Systolic pressure: 40mmHg~270mmHg
    Mean pressure: 20mmHg~235mmHg
    Diastolic Pressure: 10mmHg~215mmHg
    Pediatric:
    Systolic pressure: 40mmHg~200mmHg
    Mean pressure: 20mmHg~165mmHg
    Diastolic Pressure: 10mmHg~150mmHg
    Neonatal:
    Systolic pressure: 40mmHg~135mmHg
    Mean pressure: 20mmHg~110mmHg
    Diastolic Pressure: 10mmHg~100mmHg
    b. Upper and lower limit of alarm
    Adult:
    Systolic pressure: 40mmHg~270mmHg
    Mean pressure: 20mmHg~235mmHg
    Diastolic Pressure: 10mmHg~215mmHg
    Pediatric:
    Systolic pressure: 40mmHg~200mmHg
    Mean pressure: 20mmHg~165mmHg
    Diastolic Pressure: 10mmHg~150mmHg
    Neonatal:
    Systolic pressure: 40mmHg~135mmHg
    Mean pressure: 20mmHg~110mmHg
    Diastolic Pressure: 10mmHg~100mmHg
    SpO2 monitoring
    ■Continuous real-time measuring
    ■Adopt digital SpO2 technology, which has strong anti-interference capability
    ■Real-time display SpO2, Pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph
    ■Trend graph with the function of adaptive scaling
    ■Standard finger-clip probe for adult , binding probe for neonatal is optional
    a. SpO2 Measuring
    Range: 0%~100% (Resolution: 1%)
    Accuracy: ±2% in stage of 70%-100%, and unspecified in stage of less than 70%
    b. Pulse Rate Measuring
    Range: 30bpm~250bpm(Resolution: 1bpm)
    Accuracy: ±2bpm or ±2%, whichever is greater
    c. Measurement Performance in Weak Filling Condition: SpO2 and Pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater.
    d. Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
    Accessories
    ■A power adapter
    ■An ECG lead wire
    ■A SpO2 probe
    ■An adult NIBP cuff
    ■A base of the PM70
    Physical characteristic of host
    Dimension: 145(W)*95(H)*37(D)mm
    Weight: 400g(including battery)

     